How to reasonably choose the efficiency of junior high efficiency filter?

Views:0 Author:1 Publish Time:2023-07-01 10:51:31 Origin:Site

Various types of air filters have different standards and efficiencies. Today, Lifelt will introduce you to the application of various types of air filters in different places.

Pre-filter efficiency specifications should be reasonable

In the design of air conditioners, the efficiency of the last stage filter should be determined first according to the user's cleanliness requirements, and then the filter that plays a protective role should be selected. If this stage filter also needs to be protected, then add a filter on its upwind end. The protective filters are collectively referred to as "pre-filters".

The efficiencies of the filters at all levels should be properly matched. If the efficiency specifications of two adjacent filters differ too much, the former level will not be able to protect the latter level; if the difference between the two levels is not large, the latter level will be burdened too small.

lefilter prod_HEPA

The service life of the high-efficiency filter at the end of the clean room is 3 to 5 years, and the most important factor affecting the service life is the quality of the pre-filter.

The performance of the final filter should be reliable

When using the "G~F~H~U" efficiency specification classification, it is convenient to estimate the efficiency of the required filter. In G2~H12, set a filter every 2~4 levels, for example: G4→F7 →H10, among them, the terminal H10 (sub-high efficiency) filter determines the clean level of the air supply, F7 protects H10, and G4 protects F7.

Before the high-efficiency (HEPA) filter at the end of the clean room, there must be a filter with an efficiency specification not lower than F8 for protection; before the ultra-high-efficiency (ULPA) filter, F9-H11 filters can be used.Easy maintenance of primary filter

In areas with no wind and sand and low pollution, there is no need to install a pre-filter before the F7 filter; in urban central air-conditioning systems, G3-F6 are common primary filters.


Construction

Frame material: galvanized steel , stainless steel, aluminum, plastic;

Filter Medial: Fine fiber glass

Separator material:Aluminum / Filter paper;

Pleat HEPA filter: classic high efficiency filters, efficiency specifications: 99.99% (sodium flame method);

No Pleat HEPA filter: clean room terminal HEPA filter,efficiency specifications: 99.95%, 99.995%, 99.9995% (MPPS).

lefilter HEPA_cstrtion

Other Product Link

Pocket bag filters

V bank filter




Related cases

RELATED PRODUCTS

Air filter cartridge Solder smoke purifier Bag type dust collector

Submit Demand

Please fill in the fields below to submit your request so that we can better serve you. We promise not to disclose your personal privacy.

Whether you need to receive

Xinxiang Lefilter Filter Co., Ltd All rights reserved Record No. : 11005909-1 prepared by Yu ICP