Case study of the use of cartridge dust collectors in paint plants

Views:0 Author:1 Publish Time:2023-09-26 11:38:06 Origin:Site

The dust volume of a coating plant is relatively large, and the customer wants to solve the problem of large dust volume in the workshop, and the 

customer requires the equipment to run without stopping, otherwise the start-up operation time will be very long. After understanding these 

customer needs, our technical engineers made a pre-analysis of possible response situations. The increase in dust thickness on the surface of the 

non-stop filter media, and the increase in the resistance of the dust collector will lead to a decrease in the dust removal efficiency. Considering the 

actual needs of customers, we provide customers with professional design solutions.


filter-dust 36

Design schemes

When the pulse valve is opened, the compressed air in the air bag through the pulse valve through the small hole on the nozzle pipe, ejecting a 

high-pressure induced air flow, thereby forming an induced air flow equivalent to 1-2 times the volume of the induced air flow, together into the 

filter element, so that the filter element appears instantaneous positive pressure and produces bulging and micro-vibration, so that the dust 

deposited on the filter material falls off and falls into the ash hopper. The surface of the filter element is clean, and the dust removal work is 

sustainable and efficient without downtime.

filter-cartridge-dust-collector-21

Equipment selection

According to the above conditions, considering that the coating plant has a relatively large amount of dust, and the equipment should not stop 

running, to ensure dust removal efficiency, and at the same time to meet the factors of energy saving and high efficiency, three AT-XLC8-5 filter 

cartridge dust collectors were selected.


Design parameters

Model: AT-XLC8-5

Material: carbon steel

Number of filter cartridges: 80

Filter cartridge material: polyester non-woven fabric

Filtration area: 800m2

Recommended air volume: 48000m3/h

Filter cartridge model: ATKL-3266

Size: 5050*2300*4080mm

Blowback pressure: 0.6MPA

Voltage: 380V

Dust removal rate: 99.9%


Related Products Recommendation:

Polyester Cartridge Filter

Pleated Bag Cartridge




POPULAR INFORMATION

Air filter cartridge Solder smoke purifier Bag type dust collector

Submit Demand

Please fill in the fields below to submit your request so that we can better serve you. We promise not to disclose your personal privacy.

Whether you need to receive

Xinxiang Lefilter Filter Co., Ltd All rights reserved Record No. : 11005909-1 prepared by Yu ICP